Ultrasonic flaw detector SUB100
|
chinacoal01
Ultrasonic flaw detector SUB100 , Ultrasonic flaw detector , flaw detector
Ultrasonic flaw detector SUB100
Product Introduction
Digital Ultrasonic Flaw Detector SUB100
Features and Functions
•High right electroluminescent, strength light, weak light and sunlight viewable.
•32 independent sets of parameters can be set and save lots of inspection procedure and standards, need no test block outside, high work efficiency.
•Menu and sub-menu display in the same window, no need to search, clear at a glance, simple and convenient to operate.
•Large capacity Li battery, low power consumption design, 20+ hours run time.
•Can be connected to the printer, print inspection report and wave.
•Has auto-calibration function for normal probe, angle probe, convenient to use.
•Square wave pulse generator, amplitude and pulse width can be adjusted, suitable to test the defects of work piece with different materials and depth.
•Peak value in the gate can be captured automatically.
•DGS(AVG) curve suitable to inspect forged piece etc.
•A-scan and B-scan to be selected.
•Waveform and channel parameters can be saved into U disk directly or copied from the detector memory to the U disk then to be processed by the host computer software.
•Based the curve surface diameter to calibrate the flaw location by the curve surface calibration function.
Main Parameter
Range: (0 ~ 6000) mm
Bandwidth: (0.2 ~ 15) MHz
Material Velocity: (1000 ~ 9999) m / s
Dynamic Range: ≥ 32dB
Vertical linear error: ≤ 3%
Horizontal linear error: ≤ 0.2%
Resolution:> 40dB (5P14)
Sensitivity Leavings: 60dB (flat-bottomed deep hole 200mm2)
Rejection: (0 to 80)% Linear
Noise level: ≤ 10%
Power supply: DC 9V; lithium batteries work for 4 to 8 hours or more
Ambient temperature: (-20 ~ 50) °C
Relative Humidity: (20 ~ 95)% RH
Bandwidth: (0.2 ~ 15) MHz
Material Velocity: (1000 ~ 9999) m / s
Dynamic Range: ≥ 32dB
Vertical linear error: ≤ 3%
Horizontal linear error: ≤ 0.2%
Resolution:> 40dB (5P14)
Sensitivity Leavings: 60dB (flat-bottomed deep hole 200mm2)
Rejection: (0 to 80)% Linear
Noise level: ≤ 10%
Power supply: DC 9V; lithium batteries work for 4 to 8 hours or more
Ambient temperature: (-20 ~ 50) °C
Relative Humidity: (20 ~ 95)% RH
SUB100 Standard Configuration
No.
|
Item
|
Quantity
|
1
|
Main Body
|
1
|
2
|
Straight Beam Probe
|
1
|
3
|
Angle Probe
|
1
|
4
|
Machine-probe Cable (Q9-Q9)
|
1
|
5
|
Battery Module
|
1
|
6
|
Power Adapter (Charger)
|
1
|
7
|
Support Pillar
|
1
|
8
|
Manual
|
1
|
9
|
Instrument Case
|
1
|
No comments: